Austin 65 Gas Fireplace

The Austin 65L

The Austin 65L

Category:

Product Description

Print Friendly, PDF & Email

The Austin 65L Direct Vent Linear Gas Fireplace

 
Just like it’s little brother – the Stanford, the new Austin features a sleek contemporary linear look. At 65″ it now features our largest viewing area with our signature large flame presentation.

The Austin comes standard with our Deluxe system including 7 day programmable thermostat remote, 6 stage dual fan control and modulating valve so you can control the flame. This fireplace unit is available in gas and liquid propane (LP by special order).

Contemporary black porcelain panels, black reflective glass and 9 piece rock set all come standard with this stunning gas fireplace. A surround with safety barrier is mandatory for this model.
 
 

FEATURES

  • Borocilicate glass
  • Flush mount design
  • 38,000 BTU (Stanford)
  • Electronic Ignition
  • 7 day programmable thermostat deluxe remote
  • 7 stage modulating valve (flame control)
  • Linear style burner
  • 100% Safety shut off
  • NG or LP
  • Top vent only
  • Black Porcelain panels
  • Deluxe digital remote control
  • Dual Fan kit with 6 stage adjustable control
  • Black reflective fire glass media & 9 piece decorative rock media set
  • Dual stainless steel pan burner

Complimentary – 14 Piece Design Media Kit

Incredible value!

Free for a limited time! Purchase an Austin 65L fireplace and receive a Deluxe 14 piece log set with designer decorative media including stones, pebbles and ’embers’.

  14 Piece decorative media kit

Included Accessories

  • Termination kit
  • Extra decorative rock media – 3 piece set
  • Liquid propane conversion kit
  • Hard pipe vent
  • Flex vent to hard pipe adaptor

Surround Options

  • Clean face surround
  • Basic black surround with safety barrier
  • Design Specialties hand crafted overlays

Sierra Flame

Comparison of a Black Surround and a Clean Face

Glass Viewing Area:

18-1/2” H x 62-3/4” W

Installation Support Center

Visit our support area to view technical specification drawings, preview or download the most current manuals, brochures and repair guides.

book ruler screwdriver brochure Frequently asked questions email
Manual Specifications Repair Guide Brochures  FAQ’s  Technical Support


DISCLAIMER

Flames and flame colors on the website may appear differently in real life. To view the most accurate representation of the FIRE & ICE® flame and our regular flame sets, please visit your nearest dealer.


We reserve the right to update products, specifications and dimensions are subject to change. Please refer to the product manual to verify measurements and clearance requirements. All local building codes must be followed.



DISCLAIMER

Flames and flame colors on the website may appear differently in real life. To view the most accurate representation of the FIRE & ICE® flame and our regular flame sets, please visit your nearest dealer.


We reserve the right to update products, specifications and dimensions are subject to change. Please refer to the product manual to verify measurements and clearance requirements. All local building codes must be followed.

Specs

Gas Specifications

Framing Dimensions Viewing Area BTUs (NG) AFUE / P.4
(NG Efficiency)
Weight*
Hi Low
39” H x 70-1/2” W x 17 1/2” D
18-1/2” H x 62-3/4” W
38,000
27,000
69.10%
240 lbs.
Venting**
Ceiling /
Mantle Height
4” flex vent on exhaust side
7” flex vent on the air intake side
Internl ceiling = 58” from top of unit
Mantel height = 45”

**Venting – Any certified 2 ply flex piping can be used. Certified on Duravent, Selkirk, Metal Fab, ICC


Austin 65L specs



DISCLAIMER

Flames and flame colors on the website may appear differently in real life. To view the most accurate representation of the FIRE & ICE® flame and our regular flame sets, please visit your nearest dealer.


We reserve the right to update products, specifications and dimensions are subject to change. Please refer to the product manual to verify measurements and clearance requirements. All local building codes must be followed.

Installation

 

 

 



DISCLAIMER

Flames and flame colors on the website may appear differently in real life. To view the most accurate representation of the FIRE & ICE® flame and our regular flame sets, please visit your nearest dealer.


We reserve the right to update products, specifications and dimensions are subject to change. Please refer to the product manual to verify measurements and clearance requirements. All local building codes must be followed.

Surround Dimensions

Outside Surround Dimensions – Austin

Surround Dimensions Diagrams

Model number Outside Surround Dimensions (H x W) Description
AUSTIN-CLEAN-BLK 18.57 x 62.59 Clean Face Black Black Surround with safety barrier
AUSTIN-SB 26.10 x 69.64 Basic trim & safety barrier

 

 



DISCLAIMER

Flames and flame colors on the website may appear differently in real life. To view the most accurate representation of the FIRE & ICE® flame and our regular flame sets, please visit your nearest dealer.


We reserve the right to update products, specifications and dimensions are subject to change. Please refer to the product manual to verify measurements and clearance requirements. All local building codes must be followed.

Decorative Overlays

Design Specialties Decorative Overlays

AUSTIN-DS-ARROWS Design Specialties Handcrafted Overlay
AUSTIN-DS-MODERN Design Specialties Handcrafted Overlay
AUSTIN-DS-DIAMOND Design Specialties Handcrafted Overlay
ART-FIN Design Specialties Artisan finish – add to overlay price
SAT-NICKEL-MODERN Satin Nickel finish available for MODERN overlay – add to price

Shipped directly from Design Specialties – 4-6 weeks – Freight is additional



DISCLAIMER

Flames and flame colors on the website may appear differently in real life. To view the most accurate representation of the FIRE & ICE® flame and our regular flame sets, please visit your nearest dealer.